首頁 > 技術與支持 > FLTM BO 116-01_2007
FLTM BO 116-01_2007
點擊次數:1305 更新時間:2019-08-27

FLTM BO 116-01_2007

本頁面標準信息均來源于網絡收集,或由參與標準制定的供應商提供,只作為參考使用,為確保測試結果的準確性、節省您的時間,如需FLTM BO 116-01_2007標準詳細信息或FLTM BO 116-01_2007具體測試方法,請與我們技術人員聯系或給我們留言,我們將為您提供相關的技術支持。

 

FLTM-BO-116-01標準簡介

FLTM-BO-116-01 汽車內飾材料暴曬試驗標準:水冷式氙弧燈氣候試驗箱方法

FLTM  BO 116-01_2007標準英文版

EXPOSRE OF INTERIOR TRIM MATERIALS IN A CONTROLLED IRRADIANCE

WATER COOLED XENON-ARC APPARATS

Application

This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Ometer® with an auxiliary lantern and filters.

Apparatus Required

Operating Filter

335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the SF-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching.

Dimensions for the Ci 5000 series Weather-Ometer®:

339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Dimensions for the Ci 3, Ci 6 & Ci 4000 Weather-Ometer®:

220 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Lamp Sensor Irradiance Filter

420 nm Irradiance Filter

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Calibration Lamp

The calibration lamp must be calibrated to 420 nm with the lantern assembly removed.

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Sample & Test Conditions

Sample Conditioning

All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/-2 °C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

Test Conditions

Testing conditions such as black panel temperature, dry bulb temperature, humidity, light cycle times and dark cycle times are equivalent to those outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Table 1,Section 6.1.5.

Place the 335 nm long pass filters (SF-5 filters) or equivalent into the auxiliary lantern. Orient thelantern around the xenon-arc lamp assembly which is equipped with the Quartz/Type "S" Borosilicate filtered xenon-arc lamp source as outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Apparatus Set-p, Section 6.

Exposures are monitored based on measured light at 1.06 W/m2 -/nm@420 nm SAE J2412 –Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance XenonArc Apparatus, Table 1.

Calibration

Equipment Calibration

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A, Section A.3 and Appendix B.

Maintenance

Equipment Maintenance

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A.

Note: SF-5 auxiliary filters should be cleaned at every lamp calibration period or more frequent if necessary.

SF-5 filters and the 420 nm interference filter should be changed per the manufacturer's recommendations/or within 13,000 hours of use.

Exposure

Sample Exposure

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Test Procedure, Section 7.

Evaluation & Reporting

Sample Evaluation and Exposure Report

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Evaluating and Reporting, Section 8 and Exposure Report, Section 9.

AATCC Gray Scale, 10 Step, According to AATCC Evaluation Procedure 1/ISO 105-A02 for Evaluation of Color Change.

FLTM BO II--01_2007測試機構

 

pon request measure the gloss with a 60° glossmeter (or as specified in the applicable Engineering Standard) according to FLTM BI 110-01. Record the unexposed and exposed gloss.

Chemicals, materials, parts and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

上一篇:GB 16776-2005

下一篇:ETAG 002-1999

返回列表>>

粵公網安備44190002001386號

主站蜘蛛池模板: 国产精品国产亚洲精品不卡 | 久久99这里只有精品 | 免费看色片网站 | 夜夜涩| 亚洲天堂网2018 | 亚洲日本中文 | 免费看日本黄色片 | 日本视频www色变态 日本视频不卡 | 久久午夜宅男免费网站 | 人人做人人澡人人人爽 | 日本视频一区在线观看免费 | 久久99精品一久久久久久 | 在线亚洲精品视频 | 久久99免费视频 | 黄片毛片在线看 | 日本成人福利视频 | 中日韩欧美在线观看 | 国产一区在线观看视频 | 亚洲欧美日韩一区高清中文字幕 | 国产大片91精品免费看3 | 欧美精品1| 久久中文字幕一区二区三区 | 免费看午夜高清性色生活片 | 日本免费观看视频 | 日本一区高清 | 日韩性大片免费 | 欧美亚洲国产精品久久 | 亚洲视频在线免费播放 | 在线观看视频亚洲 | 日韩无遮挡| 欧洲乱码专区一区二区三区四区 | 欧美精品一区二区三区在线 | 免费观看欧美成人禁片 | 黄色片xxxxx 黄色片韩国 | 欧美jizz8性欧美18 | 日本xxxx色视频在线观看免费 | 日本黄色片在线免费观看 | 亚洲午夜视频 | 日本高清视频在线观看 | a毛片全部免费播放 | 欧美一区二区三区精品影视 |